Dressing Drum (Sterilizer Shallow)
- Flawless in concept, design & finish.
- Lid Snaps fit on the body.
- Belt fits snugly and uniformly on the body thanks to precision clip which keep the belt in fair tension.
- Belt slots and perforations of the body correspond accurately.
- Custom designed chain for comfortable latching.
- Configuration, design & Material confirms as per IS 3831 in all sizes.
Size
350*240mm, 275*240mm, 275*132mm, 225*225mm, 350*130mm
Pressure Type Vertical Portable Sterilizer (Auto Clave)
- Stainless Steel seamless sterilizer
- User's friendly master piece with several productive features.
- Thermally insulated and vulcanised poly chloroprene (synthetic Rubber) gasket.
- The construction of the sterilizer is ensured an easy and safe handling.
- Handles holding lugs & knobs afford safe handling inspite of high temperature.
- It can run on any fuel e.g. charcoal, kerosene, Gas or electricity.
Size
350mm (dia)*300-325(height)
Instrument Sterilizer
- A Product of choice in the medical field.
- Seamless shell leyer operated Lid fitted with full proof mechanism control excessive steam escape and restricts condensate with in the shell.
- incredible synchroised manoevrability of lid, due to statistically perforated tray for flushing and entry of water.
- Highly adoptable of your growing needs.
- configuration design and material as per IS : 5022.
Size
Large : 510*200*150mm, Medium : 430*200*150mm, Small : 300*150*125mm
Fumigator Aerosol Disinfector
- The Fumigator converts farmuline in to Aerosol form which is 100% biocidol with an adequate amount of penetrability to destroy every spores.
- Aerosol farmuline & water combines to work with a vengeance, permeating every crack and crevice.
- Fumigator works with an amazing quickness. its powerful mechanism instantly converts liquid farmuline in to true aerosol particles. The portable, handy and easy to operate unit can be handled by any staff member or even a room boy. There is virtually no maintenance required.
- Every Fumigator Aerosol disinfactor passes through stringent quality control tests at various stages of manufacturing before it reaches you.
Portable Autoclave Single Drum
- The portable single drum Autoclave is highly efficient apparatus which is designed to meet the requirements of small dispensaries, nursing homes, laboratories, medical missions, clinics, ships, Operation theaters, Pharmaceuticals etc. It is very simple to operate and economical to use.
- The container is seamless made of thick stainless steel 304.
Size
| Dimensions | 240 x 350 mm P. Type |
| 300 x 300 mm P. Type | 300 x 500 mm P. Type |
| 240 x 240 mm P. Type | 300 x 380 mm P. Type |
Kidney Trays
- Made form stainless steel sheet. All dimension are as per IS-3992-1982.
| I | II | III | IV | V | |
|---|---|---|---|---|---|
| Length | 150 | 200 | 25 | *250 | 300 |
| Width | 70 | 90 | 100 | 150 | 130 |
| Height | 30 | 40 | 50 | 40 | 60 |
Size
300*300 mm P.Type
Lotion Bowls
- Made form stainless steel sheet. All dimension are as per IS-3991-1982.
| I | II | III | IV | V | VI | |
|---|---|---|---|---|---|---|
| INNER DIA | 100 | 125 | 150 | 200 | 250 | 300 |
| BASE DIA | 50 | 62 | 7.5 | 100 | 125 | 150 |
| CAPACITY (In Ltrs.) | 0.2 | 0.4 | 0.8 | 1.6 | 3.0 | 4.0 |
Instrument Trays
- Made form stainless steel sheet. All dimension are as per IS-3993-1982. Minimum finished thickness is 0.5 mm.
| I | II | III | IV | V | VI | |
|---|---|---|---|---|---|---|
| Length | 200 | 250 | 300 | 300 | 350 | 450 |
| Width | 150 | 200 | 150 | 250 | 250 | 300 |
| Height | 50 | 50 | 50 | 50 | 50 | 50 |
Sponge Bowls
- Made form stainless steel sheet. All dimension are as per IS-3991-1982.
| I | II | III | |
|---|---|---|---|
| DIA INTERNAL | 125 | 150 | 200 |
| DIA BOTTOM | 90 | 110 | 145 |
| HEIGHT | 57 | 60 | 80 |
| CAPACITY (In Ltrs.) | 0.6 | 1.0 | 2.0 |
FOGGER MACHINE
- FUMIGATOR, OT FOR FORMALIN
| Technical specification for Fogger machine |
|---|
| Input Power : 220 VAC, 3.5 AMP, 50Hz Consistant particle size. |
| Generation : 5-15 MICRONS VMD |
| Reach : 20-30 ft distance & 18-20 ft height. |
| Space treatment : UP to 7000 cuft& even larger. |
| Nozzle Assembly : Non Rotating Vortex Design, Non Clogging. |
| Power Hade Housing : High Grade Engg. Plastics. |
| Though & corrosion resistant. |
| Chemical Solution Tank : Capacity – 5 liters |
| Precision Metering System : Liquid Discharge rate : 0-200 ml/min |
| Adjustable by rotating knob (8 turns). |
| Intake Air Filter : Primary / Secondary Filteration. |
| Empty Weight : 4.6 kg |
HIGH PRESSURE STEAM STERILIZER VERTICAL
- WINGNUT TYPE / RADIAL LOCKING TYPE
| The Inner Chamber is of S.S. 304 Salem 16 G and other Jacket is of Brass/ S.S. Covered by M.S. Sheet Painted or covered by S.S. Sheet. |
|---|
| The lid of thick gunmetal chrome plated or S.S. complete with pressure gauge safety valves, steam release cock, water level, water inlet and outlet valves. |
| Working pressure of Autoclave as per requirement of purchase approx.. 1.2 or 1.5 kgf/cm2. |
| Automatic pressure control and timer can be fitted with extra charges. |
| The radial Locking system of equipment made out of Mild Steel with electroplating chrome. |
| Dimensions: 300x500 mm, 350x550 mm, 400x600 mm, 400x900 mm |
AUTOCLAVE VERTICAL (SQUARE TYPE)
| Autoclave Body is crafted by CNC Machine fitted with standing Wheel. Outer Body is made AISI-304 Stainless Steel. Inner Chamber is made up 16 Gauge AISI-304 Grade Stainless Steel. Lid is thick AISI 304 Grade Stainless Steel. |
| Easy to operate:- -Equipped with digital Temperature-Control -Inbuilt Timer -Low Water Cut |
| Dimensions 300x500 mm 350x500 mm 400x600 mm |
HORIZONTAL AUTOCLAVE (DRY STERILIZATION MODEL) CYLINDRICAL
| Construction: The unit should have outer chamber, inner chamber boiler, lid and jacket –all should be made of 304-grade stainless steel. The jacket and inner chamber should be made of stainless steel sheets. For controlling sterilization cycle, a three-way valve or a multiport valve/three way valve- made of S.S/Brass should be provided. It should be supplied completely with vacuum breaker, water level indicator, steam trap and automatic pressure control switch. The whole unit should be mounted on a robust tubular stand. To work on 1/3 phase, 440 volts A.C. supply. |
| Working pressure: The pressure inside the chamber should be variable from 5 psi. to 21 (121-1250 C) psi. But the normal recommended pressure for sterilization process is 1.2 kgf /cm sq/g (22psi) |
| Standard controls: Door: Single door shall be fitted with radical shooting arm. Accidental vacuum breaker A safety device or jacket against accidental vacuum in it and to remove residual air from it. |
| Safety valve: A safety device against excess pressure in jacket and steam generator. |
| Chamber condensate line: incorporated with spiral thermostatic steam trap and check valve for perfect condensation from chamber to achieve optimum temperature. |
| Electrical Control Box: Equipped with air break contractor of ':CUT. HAMM':make, toggle switch and nos. indicating neon lamps. |
| FEATURES INCORPORATED IN BASIC UNIT: 1.Automatic pressure control switch – This semi-automatic device controls the pressure inside the chamber mechanically and cuts-off the current from the heating elements, when the desired/ set pressure value level is attained inside the chamber and restarts the mechanism once the pressure inside the chamber falls from the desired level. 2.Automatic low water cut-off device- This device is a safety device which protects the heaters from running dry. This device ensures that the machine is automatically switched off in case the desired water level falls below the prescribed level. 3. Micro processor based PID Controller- It shows the temperature of the chamber. With alarm and timer. |
| Dimension (DIA * (Depth) 400 x 600 mm, 400 x 900 mm, 400 x 1200 mm, 500 x 1200 mm, 600 x 1200 mm |
VERTICAL AUTOCLAVE (WINGNUT TYPE/RADIAL LOCKING TYPE)
| As a specific requirement for Clinic, portable Vertical Cylinder Single Chamber Autoclave wingnut Type / Radial Locking System Optional Lid in cylindrical diameter and outer chamber made of Stainless Steel, Top lid of Solid Stainless Steel die press equipped with steam release. Double safety valves and drain cock. Specially designed heat resistant gasket. New type of element of 2Kw/3Kw is covered by same metal removable cover to protect the electric shock. The equipment is fitted with specially designed LOW WATER LEVEL CUT OFF DIGITAL DEVICE SYSTEM. This system will protect the element at the low water level and indicate at the control board and equipment's gets automatically cut off the electricity. With the same specifications as above we make automatic autoclave which fitted with high pressure control state electronic time programme system. |
| Dimensions 300x500 mm, 350 x 550 mm,400x600 mm, 400x900 mm,500x750 mm |

